ilorest command로 할 수 있는 범위가 너무 광범위해서
점검 목적으로 자주쓰는 커맨드를 공유합니다.
1. ilorest serverinfo
- ilorest serverinfo --all
> 모든 정보 출력
- ilorest serverinfo -fw
> 펌웨어정보출력
[root@ ~ ]# ilorest serverinfo -fw iLOrest : RESTful Interface Tool version 3.6.0.0 Copyright (c) 2014-2022 Hewlett Packard Enterprise Development LP --------------------------------------------------------------------------------------------------------------------- ------------------------------------------------ Firmware: ------------------------------------------------ iLO 5 : 2.71 Jul 04 2022 System ROM : U32 v2.66 (05/17/2022) Intelligent Platform Abstraction Data : 16.4.0 Build 24 System Programmable Logic Device : 0x31 Power Management Controller Firmware : 1.0.8 Power Supply Firmware : 1.05 Power Supply Firmware : 1.04 Innovation Engine (IE) Firmware : 0.2.2.3 Server Platform Services (SPS) Firmware : 4.1.4.601 Server Platform Services (SPS) Descriptor : 1.2 0 Redundant System ROM : U32 v2.66 (05/17/2022) Intelligent Provisioning : 3.76.2 Power Management Controller FW Bootloader : 1.1 HPE Smart Storage Energy Pack 1 Firmware : 0.70 HP Ethernet 1Gb 4-port 366FLR Adapter : 1.3089.0 HPE Smart Array P408i-a SR Gen10 : 5.32 Embedded Video Controller : 2.5 480GB 6G SATA SSD : 7CV10100 480GB 6G SATA SSD : 7CV10100 |
- ilorest serverinfo -sw
> ilorest 버전 출력
[root@ ~ ]# ilorest serverinfo -sw iLOrest : RESTful Interface Tool version 3.6.0.0 Copyright (c) 2014-2022 Hewlett Packard Enterprise Development LP |
- ilorest serverinfo -processors
> CPU 정보 출력
[root@ ~ ]# ilorest serverinfo --processors iLOrest : RESTful Interface Tool version 3.6.0.0 Copyright (c) 2014-2022 Hewlett Packard Enterprise Development LP --------------------------------------------------------------------------------------------------------------------- ------------------------------------------------ Processor : ------------------------------------------------ Processor 1: Model: Intel(R) Xeon(R) Silver 4208 CPU @ 2.10GHz Step: 7 Socket: Proc 1 Max Speed: 4000 MHz Speed: 2100 MHz Cores: 8 Threads: 16 L1-Cache: 512 KB L2-Cache: 8192 KB L3-Cache: 11264 KB Health: OK |
- ilorest servierinfo -memory
[root@ ~ ]# ilorest serverinfo --memory iLOrest : RESTful Interface Tool version 3.6.0.0 Copyright (c) 2014-2022 Hewlett Packard Enterprise Development LP --------------------------------------------------------------------------------------------------------------------- ------------------------------------------------ Memory/DIMM Board Information: ------------------------------------------------ Advanced Memory Protection Status: A3DC Board CPU: 1 Total Memory Size: 131072 MiB Board Memory Frequency: 2400 MHz Board Memory Voltage: 1200 MiB Board CPU: 2 Total Memory Size: 0 MiB Board Memory Frequency: 2400 MHz Board Memory Voltage: 1200 MiB ------------------------------------------------ Memory/DIMM Configuration: ------------------------------------------------ Location: PROC 1 DIMM 3 Memory Type: DRAM DDR4 Capacity: 32768 MiB Speed: 2400 MHz Status: GoodInUse Health: OK Location: PROC 1 DIMM 5 Memory Type: DRAM DDR4 Capacity: 32768 MiB Speed: 2400 MHz Status: GoodInUse Health: OK Location: PROC 1 DIMM 8 Memory Type: DRAM DDR4 Capacity: 32768 MiB Speed: 2400 MHz Status: GoodInUse Health: OK Location: PROC 1 DIMM 10 Memory Type: DRAM DDR4 Capacity: 32768 MiB Speed: 2400 MHz Status: GoodInUse Health: OK |
- ilorest serverinfo -thermals
> 각 장치별 온도 체크
------------------------------------------------ Thermal: ------------------------------------------------ Sensor #1: Location: Intake Current Temp: 26 C Critical Threshold: 42 C Fatal Threshold: 47 C Health: OK Sensor #2: Location: CPU Current Temp: 40 C Critical Threshold: 70 C Fatal Threshold: None C Health: OK Sensor #4: Location: SystemBoard Current Temp: 35 C Critical Threshold: 90 C Fatal Threshold: None C Health: OK 이하생략 |
- ilorest serverinfo -power
> 파워서플라이 상태 출력
------------------------------------------------ Power: ------------------------------------------------ Total Power Capacity: 1000 W Total Power Consumed: 53 W Power Metrics on 20 min. Intervals: Average Power: 54 W Max Consumed Power: 91 W Minimum Consumed Power: 53 W ------------------------------------------------ Power Supply 1: ------------------------------------------------ Power Capacity: 500 W Last Power Output: 47 W Input Voltage: 218 V Input Voltage Type: ACHighLine Hotplug Capable: True iPDU Capable: False Health: OK State: Enabled ------------------------------------------------ Power Supply 2: ------------------------------------------------ Power Capacity: 500 W Last Power Output: 6 W Input Voltage: 220 V Input Voltage Type: ACHighLine Hotplug Capable: True iPDU Capable: False Health: OK State: Enabled ------------------------------------------------ PowerSupply Redundancy Group 1 ------------------------------------------------ Redundancy Mode: Failover Redundancy Health: OK Redundancy State: Enabled |
- ilorest serverinfo -system
> 장치명, 바이오스버전, 시리얼넘버, MAC 등 시스템에 대한 간단 정보 출력
------------------------------------------------ System: ------------------------------------------------ Model: HPE ProLiant DL360 Gen10 Bios Version: U32 v2.66 (05/17/2022) Serial Number: CNX238 Embedded NIC Count: 4 1 MAC: d4:f5:ef:90:85:fc 2 MAC: d4:f5:ef:90:85:fd 3 MAC: d4:f5:ef:90:85:fe 4 MAC: d4:f5:ef:90:85:ff |
- ilorest serverinfo --showabsent
> 상기 모든 정보 한번에 출력
2. ilorest smartarray
- ilorest smartarray --physicaldrives
> 모든 컨트롤러의 디스크 출력
--------------------------------------------------------------------------------------------------------------------- Controllers: [0]: Slot 0 - HPE Smart Array P408i-a SR Gen10 Physical Drives: [1I:1:1]: Model INTEL SSDSC2KB480GZ, Location 1I:1:1, Type SSD, Serial PHYI23340480BGN - 457862 MiB [1I:1:2]: Model INTEL SSDSC2KB480GZ, Location 1I:1:2, Type SSD, Serial PHYI23340480BGN - 457862 MiB |
- ilorest smartarray --logicaldrives
> 논리드라이브의 정보 출력
--------------------------------------------------------------------------------------------------------------------- Controllers: [0]: Slot 0 - HPE Smart Array P408i-a SR Gen10 Logical Drives: [1]: Name Logical Drive 1 VUID 600508B1001C06C31BBE11AE812A402C - 457830 MiB Data Drives: @odata.context :/redfish/v1/$metadata#HpeSmartStorageDiskDrive.HpeSmartStorageDiskDrive @odata.etag :W/"55E3DB09" @odata.id :/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/0/ @odata.type :#HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive Id :0 BlockSizeBytes :512 CapacityGB :480 CapacityLogicalBlocks :937703088 CapacityMiB :457862 CarrierApplicationVersion :11 CarrierAuthenticationStatus :OK CurrentTemperatureCelsius :40 Description :HPE Smart Storage Disk Drive View DiskDriveStatusReasons :['None'] DiskDriveUse :Data EncryptedDrive :False FirmwareVersion : Current : VersionString :7CV10100 InterfaceSpeedMbps :6000 InterfaceType :SATA LegacyBootPriority :None Location :1I:1:1 LocationFormat :ControllerPort:Box:Bay MaximumTemperatureCelsius :47 MediaType :SSD Model :INTEL SSDSC2KB480GZ Name :HpeSmartStorageDiskDrive PowerOnHours :599 SSDEnduranceUtilizationPercentage :0 SerialNumber :PHYI23 Status : Health :OK State :Enabled UncorrectedReadErrors :0 UncorrectedWriteErrors :0 @odata.context :/redfish/v1/$metadata#HpeSmartStorageDiskDrive.HpeSmartStorageDiskDrive @odata.etag :W/"C294CD64" @odata.id :/redfish/v1/Systems/1/SmartStorage/ArrayControllers/0/DiskDrives/1/ @odata.type :#HpeSmartStorageDiskDrive.v2_1_0.HpeSmartStorageDiskDrive Id :1 BlockSizeBytes :512 CapacityGB :480 CapacityLogicalBlocks :937703088 CapacityMiB :457862 CarrierApplicationVersion :11 CarrierAuthenticationStatus :OK CurrentTemperatureCelsius :40 Description :HPE Smart Storage Disk Drive View DiskDriveStatusReasons :['None'] DiskDriveUse :Data EncryptedDrive :False FirmwareVersion : Current : VersionString :7CV10100 InterfaceSpeedMbps :6000 InterfaceType :SATA LegacyBootPriority :None Location :1I:1:2 LocationFormat :ControllerPort:Box:Bay MaximumTemperatureCelsius :47 MediaType :SSD Model :INTEL SSDSC2KB480GZ Name :HpeSmartStorageDiskDrive PowerOnHours :599 SSDEnduranceUtilizationPercentage :0 SerialNumber :PHYI233 Status : Health :OK State :Enabled UncorrectedReadErrors :0 UncorrectedWriteErrors :0 |
3. ilorest serverlogs
- ilorest serverlogs --selectlog=AHS
> HP에 로그를 제출하거나 HP 홈페이지 메니지먼트에서 서버의 상태를 확인하고자 할때 생성하는 로그
커맨드를 실행한 경로에 HPE_[SerialNumber]_[DATE].ahs로 생성
- ilorest serverlogs --selectlog=IML
> 하드웨어 IML로그를 확인 할 수 있다.
반응형
'SYSTEM > Command' 카테고리의 다른 글
hp ssacli SSD write speed up / HP DL360 G10, P408i-a, Not install Cache battery (0) | 2022.11.16 |
---|---|
Linux Check SSD / Intel SSD check / Samsung SSD check (0) | 2022.08.23 |